VABIO580 Auto Hematology Analyzer is a bench top system, offering reliable and accurate
5 part differential testing and significantly improves sample handling by eliminating manual sample loading which is a feature that saves time, lowers operational costs and increases laboratory workflow efficiency.
It uses only 20 ul of blood to have a 29 parameters result. It is possible to load up to 60 samples simultaneously and it supports continuous sample loading. Customization on reference range and report formats, patient historical check, workload statistics and LIS connection are just some of the advanced features of the analyzer which provides laboratory confort and productivity.
* Laser scatter + Chemical dye + Flow cytometry
* 5-part differentiation, 29 parameters
* Low sample volume as 20 ul
* Up to 80samples per hourwith autoloader
* Loading up to 60 samples simultaneously
* Support continuous sample loading
* Peripheral blood, venous blood and pre-diluted blood counting
* Close and open vial modes
* STAT function
* Powerful capability to flag abnormal cellsand up to 20 user-defined alarm ranges
* Working status self-test and reagent volume self-detection
* Automated test re-running, with defined rules
* Error removal and sleep/wakeup functions
* Large storage capacity: up to 100,000 samples
* Recommended or customizable decision rules for re-exam abnormal samples
* QC and calibration management
* Support uni- or bi-directional LIS
Principles
Semiconductor laser scatter, Flow Cytometry (WBC Diff)
Impedance method for WBC, RBC, PLT counting
Cyanide-free reagent for Hemoglobin test
Parameters
WBC, Lym%, Lym#,Mon%, Mon#,Neu%, Neu#,Eos%, Eos#, Bas%, Bas#, RBC, HGB, HCT, MCV, MCH, MCHC, RDW-CV, RDW-SD, PLT, PDW, MPV, PCT, P-LCC and, P-LCR and 4 research parameters LIC%, LIC#, ALY%, ALY#
1 3D and 3 2D 3 scatter grams and 3 histograms
Throughput
Up to 80 samples per hour with autoloader
Sample Volume
≤20ul
Test Mode
CBC CBC+DIFF
Counting Modes
Whole Blood, pre-diluted blood, peripheral blood
Performance
Carryover Reproducibility (CV%) Linearity
WBC ≤0.5% ≤2.0% (4-15×109/L) 0.00-300×109/L
RBC ≤0.5% ≤1.5% (3.5-6.0×1012/L) 0.00-8.5×1012/L
HGB ≤0.5% ≤1.5% (110-180g/L) 0-250g/L
PLT ≤1.0% ≤4.0% (150-500×109/L) 0.00-3000×109/L
Data Storage Capacity
Up to 100,000 results including numeric and graphical information
Communication
LAN port supports HL7 protocol
Operating Environment
Temperature: 15oC-30oC
Humidity: 30-85%
Air Pressure: 70-106 kPa
Power Requirement
A.C. 100-240V ≤300VA 50/60Hz
Dimension and Weight
620mm(L) × 620mm(W) × 535mm(H)
Weight: 56kg